MODELPREFIX = O | GPF-U500S12 | GPF-U500S15 | GPF-U500S24 | GPF-U500S27.5 | GPF-U500S48 |
OUTPUT | DC Output | 12V | 15 | 24V | 27.5V | 48V |
Rated Current | 40A | 33A | 20A | 18A | 10A |
CurrentRange Note 1 | 0~40A | 0~33A | 0~20A | 0~18A | 0~10A |
Ripple and Noise Note 2 | 120mV | 150mV | 240mV | 270mV | 480mV |
Voltage ADJ. Range | 11.2V-14.2V | 13.0V-17.0V | 21.6V-26.4V | 22.0V-33.0V | 40V-50V |
Voltage Accuracy | ±3.0% | ±3.0% | ±3.0% | ±3.0% | ±3.0% |
Line Regulation | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Load Regulation | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Set-up Time | <4.0S (115Vac input, Full load);<2.0S (230Vac input, Full load) |
Hold up Time | >20mS(230Vac input, Full load) |
Temperature Coefficient | ±0.03%/℃ |
Overshoot and Undershoot | <5.0% |
INPUT | VoltageRange | 90Vac~264Vac |
FrequencyRange | 47Hz~63Hz |
Power Factor(Typical) | PF>0.99/115VAC PF>0.95/230VAC |
Efficiency ( Typical) | 115Vacinput | 78% | 80% | 81% | 80% | 82% |
230Vacinput | 82% | 82% | 86% | 86% | 85% |
AC Current (max.) | 7.3A 2.5A | 7.5A | 7.5A | 7.5A | 7.3A |
Inrush Current (Typical) | <20A@115Vac <40A@230Vac Cold start |
Leakage Current | Input—output:<0.25mA Input—PG:<3.5mA |
PROTECTION | Over Load | 105%~140% of rated output current, constant current limiting,auto recover |
Over Voltage | 115%~150% of rated output voltage, shut down |
Over Temperature | 95℃+5℃(detect on heatsink of power transistor);shut down,auto recover after the temperature goes down |
Fan ON/OFF Control | Output load>55% rating or inside temperature >65℃,FANON |
Function | Romote ON/OFF Control | R.C./G: Short = power on; Open=power off |
ENVIRONMENT | Operating amb. Temp. & Hum. | -10℃~60℃; 20%~90%RH No condensing(refer to the derating curve) |
Storage Temp. & Hum. | -25℃~85℃; 10%~95%RH No condensing |
SAFETY&EMCNote 3 | Safety Standards | UL60950-1; EN60950-1:2006 |
Withstand Voltage | Primary-Secondary:3.0KVac;≤10mA .Primary-PG:1.5KVac;≤10mA. Secondary-PG:0.5KVDC;≤10mA. |
Isolation Resistance | ≥50Mohms |
EMI Conduction&Radiation | Compliance to EN55022 ClassA |
Harmonic Current | Compliance to EN61000-3-2,17625.1-2003 |
EMSImmunity | Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level, criteria A |
OTHERS | MTBF (MIL-HDBK-217F) | More than 100,000Hrs (25℃, Full load) |
Dimension (L*W*H) | 170×117×94mm |
Packing | 6PCS/CTN, G.W:13.2kgs |
Cooling method | Cooling by forced air (built-in DC fan) |