Technical Data: NJ20+U1+N
General specifications |
Switching element function | NAMUR, NC |
Rated operating distance | 20 mm |
Installation | not embeddable |
Output polarity | NAMUR |
Assured operating distance | 0 ... 16.2 mm |
Reduction factor rAl | 0.4 |
Reduction factor rCu | 0.3 |
Reduction factor r303 | 0.85 |
Nominal ratings |
Nominal voltage | 8.2 V (Riapprox. 1 kΩ) |
Switching frequency | 0 ... 150 Hz |
Current consumption | |
| Measuring plate not detected | ≥ 3 mA |
| Measuring plate detected | ≤ 1 mA |
Compliance with standards and directives |
Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
Approvals and certificates |
FM approval | |
| Control drawing | 116-0165F |
UL approval | cULus Listed, General Purpose |
CSA approval | cCSAus Listed, General Purpose |
CCC approval | Products with a maximum operating voltage of ≤36 V do not bear a CCC marking because they do not require approval. |
Ambient conditions |
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
Mechanical specifications |
Connection type | screw terminals |
Core cross-section | up to 2.5 mm2 |
Housing material | PBT |
Sensing face | PBT |
Protection degree | IP68 |
General information |
Use in the hazardous area | see instruction manuals |
| Category | 1G; 2G; 1D |