ACRK型 | 大流量多级浸水式冷却泵 | | 型号 | ACRK2 | ACRK4 | ACRK8 | ACRK16 | 频率(Hz) | 50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 | 标准流量(L/min) | 33.3 | 33.3 | 67 | 67 | 133 | 133 | 267 | 267 | 流量范围(L/min) | 16.7~ 58 | 16.7~75 | 33.3~133 | 43.3~150 | 100~200 | 117~242 | 133~367 | 167~433 | 最大压力(bar) | 24 | 24 | 21.8 | 17 | 22 | 19.5 | 11.8 | 10.6 | 输出功率(Kw) | 0.37~3.0 | 0.37~4.0 | 0.37~4.0 | 0.75~4.0 | 0.75~7.5 | 1.5~7.5 | 1.1~7.5 | 1.5~7.5 | 温度范围(°C) | 0~90 | 0~90 | 0~90 | 0~90 | 0~90 | 0~90 | 0~90 | 0~90 |
|
| |
|
|
AHCP-VQ型 | | |
| High pressure泵是容积式叶片结构,具有耐用性及高压力,使用于高速钻床高性能设备等。叶片及腔体式特殊材质耐磨性高。 High pressure泵非自吸式,所以必须同吸入泵组合使用,洗口侧应设置过滤网,防止异物吸入。 |
| | rpm 转数 | Pressure 压力 (kg/cm²) Type 型号 | Discharge delivery 流量(l/min) | Motor out-let 电机功率 kw | Net weight 重量 kg | 0 kg /cm | 10 kg /cm² | 20 kg /cm² | 30 kg /cm² | 40 kg /cm² | 50 kg /cm² | 55 kg /cm² | 60 kg /cm² | 70 kg /cm² | 80 kg /cm² | 90 kg /cm² | 100 kg /cm² | 1000 50Hz | AHCP-VQ25-40 | 28.0 | 27.0 | 26.0 | 24.0 | 20.0 | | | | | | | | 3.0 | | AHCP-VQ25-55 | 28.0 | 27.0 | 26.0 | 25.0 | 24.0 | 22.0 | 20.0 | | | | | | 4.0 | | AHCP-VQ25-70 | 28.0 | 27.0 | 26.0 | 25.0 | 24.0 | 22.0 | 21.5 | 21.0 | 20.0 | | | | 5.5 | | AHCP-VQ25-100 | 28.0 | 27.0 | 26.0 | 25.0 | 24.0 | 23.0 | 22.5 | 22.0 | 21.5 | 21.0 | 20.5 | 20.0 | 7.5 | | 1200 60Hz | AHCP-VQ25-40 | 32.0 | 31.5 | 30.0 | 29.0 | 25.0 | | | | | | | | 3.0 | | AHCP-VQ25-55 | 32.0 | 32.0 | 31.5 | 30.0 | 28.5 | 27.0 | 25.0 | | | | | | 4.0 | | AHCP-VQ25-70 | 32.0 | 32.0 | 31.5 | 30.0 | 29.0 | 27.5 | 26.5 | 26.0 | 25.0 | | | | 5.5 | | AHCP-VQ25-100 | 32.0 | 32.0 | 31.5 | 30.0 | 29.0 | 28.0 | 27.5 | 27.0 | 26.5 | 26.0 | 25.5 | 25.0 | 7.5 | | 1000 50Hz | AHCP-VQ40-40 | 44.0 | 42.0 | 39.0 | 36.0 | 34.0 | | | | | | | | 4.0 | | AHCP-VQ40-55 | 44.0 | 42.0 | 39.0 | 37.0 | 36.0 | 35.0 | 34.0 | | | | | | 5.5 | | AHCP-VQ40-70 | 44.0 | 42.0 | 40.0 | 39.0 | 38.0 | 37.0 | 36.0 | 35.0 | 34.0 | | | | 7.5 | | AHCP-VQ40-100 | 44.0 | 42.0 | 40.0 | 39.0 | 38.0 | 37.0 | 36.5 | 36.0 | 35.5 | 35.0 | 34.5 | 34.0 | 11.0 | | 1200 60Hz | AHCP-VQ40-40 | 50.0 | 48.0 | 45.0 | 42.0 | 40.0 | | | | | | | | 4.0 | | AHCP-VQ40-55 | 50.0 | 48.0 | 45.0 | 43.0 | 42.0 | 41.0 | 40.0 | | | | | | 5.5 | | AHCP-VQ40-70 | 50.0 | 48.0 | 46.0 | 45.0 | 44.0 | 43.0 | 42.0 | 41.0 | 40.0 | | | | 7.5 | | AHCP-VQ40-100 | 50.0 | 49.0 | 48.0 | 47.0 | 46.0 | 45.0 | 44.0 | 43.0 | 42.0 | 41.0 | 40.5 | 40.0 | 11.0 | |
|
| |
|
---------------------------------------------------------------------------- |
ACHK型 | | | 型号 | ACHK2 | ACHK4 | 频率(Hz) | 50 | 60 | 50 | 60 | 标准流量(L/min) | 33.3 | 33.3 | 67 | 67 | 流量范围(L/min) | 16~ 58.3 | 25~67 | 33.3~133 | 43.3~150 | 最大压力(bar) | 5.6 | 6.8 | 4.6 | 4.0 | 输出功率(Kw) | 0.37~1.1 | 0.37~1.1 | 0.37~1.1 | 0.55~1.1 | 温度范围(°C) | -10~90 | -10~90 | -10~90 | -10~90 |
|
| | 生产标准电压 200/220V 50/60Hz、200-230V/380-415V 50Hz、220-240V/380-440V 60Hz。另外按照预定,可生产特殊电压。 | |
|
---------------------------------------------------------------------------- |
ACH型 |
吸式冷却泵 | | | 型号 | ACH2 | ACH4 | 频率(Hz) | 50Hz | 60Hz | 50Hz | 60Hz | 标准流量(L/min) | 33.3 | 33.3 | 67 | 67 | 流量范围(L/min) | 16~ 58.3 | 25~67 | 33.3~133 | 43.3~150 | 最大压力(bar) | 5.6 | 6.8 | 4.6 | 4.0 | 输出功率(Kw) | 0.37~1.1 | 0.37~1.1 | 0.37~1.1 | 0.55~1.1 | 温度范围(°C) | -10~90 | -10~90 | -10~90 | -10~90 |
|
|
|