供应力特科尔Cole Hersee工程机械电源总开关 75920-10
|
Installation | fits standard Master Disconnect Switch hole |
Operating temperature range | -40degC to +85degC |
Corrosion test | 96hours salt spray test to ASTM standard |
Vibration test | 10-500Hz to SAE J1455 |
Shock test | To SAE J1455 |
Battery terminals | 3/8" - 24 70-90 in-lbs (8-10Nm) |
Mounting hardware | 3/4" - 16 18ft-lbs max (24.4Nm) |
Operating voltage | 6V min 36V max |
Continuous current | 12V 300A max, 24V 250A max, 36V 200A max |
Intermittent current | 12V 1000A 90sec On 5 min Off |
Intermittent current | 12V 1500A 60sec On 5 min Off |
Intermittent current | 12V 2000A 30sec On 5 min Off |
Intermittent current | 12V 3000A 15sec On 5 min Off |
Description | Master Battery Disconnect Switch |
Continuous Rating | 300A max at 12V, 250A max at 24V, 200A max at 36V DC |
intermittent Rating | 1000A at 12V 90sec On, 5min Off, 3000A at 12V 15sec On, 5min Off |
Lockout | Integral holes accept padlock. Meets OSHA requirements |
Case | Engineering thermoplastic |
Sealing | Waterproof and dustproof to IP67, tested to SAE J1455 |
Bezel imprint | 'On' and 'Off' |