深圳市海亿自动化设备有限公司主营三菱PLC,变频器,伺服电机,人机界面,授权代理台达,威纶!库存齐全,价格优惠,让您满意,提供技术支持和维修业务!
欢迎致电13410662081冯小姐 工作QQ:2355879013 竭诚为您服务,期待您的来电
我们将免费为您提供选型资料、编程软件、使用手册和技术支持!
台达VFD变频器目前已在工业自动化市场建立广泛的品牌知名度。各系列产品针对力矩、损耗、过载、超速运转等不同操作需求而设计,并依据不同的产业机械属性作调整;可提供客户最多元化的选择,并广泛应用在工业自动化控制领域。
优势与特点:
1、高功率体积比
2、品质卓越
3、提供通用型、高性能系列产品;并能针对不同行业开发专用产品
VFD40WL21A
VFD001L21A
VFD002L21A
VFD004L21A
VFD007L21A
VFD015L21W
VFD022L21W
VFD002S21A
VFD004S21A
VFD007S21A
VFD015S21D
VFD022S21D
VFD004S43A
VFD007S43A
VFD015S43D
VFD022S43D
VFD004M21A
VFD004M21A-ZA
VFD007M21A
VFD007M21A-ZA
VFD015M21A
VFD015M21A-ZA
VFD022M21A
VFD007M43B
VFD007M43B-ZA
VFD015M43B
VFD015M43B-ZA
VFD022M43B
VFD022M43B-ZA
VFD037M43A
VFD055M43A
VFD075M43A
VFD004M23A
VFD007M23A
VFD015M23A
VFD022M23B
VFD037M23A
VFD055M23A
VFD007M21A-Z
VFD015M21A-Z
VFD022M23B-Y
VFD007M11A-Z
VFD004M21B-D
VFD002DD21A
VFD004DD21A
VFD002DD21AB
VFD004DD21AB
VFD002DD21E
VFD004DD21E
ECMD-B91207MS
ECMD-B91608MS
VFD007B21A
VFD015B21A
VFD022B21A
VFD007B43A
VFD015B43A
VFD015B43A-ZA
VFD022B43B
VFD037B43A
VFD055B43A
VFD075B43A
VFD110B43A
VFD150B43A
VFD185B43A
VFD220B43A
VFD300B43A
VFD370B43A
VFD450B43A
VFD550B43C
VFD750B43C
VFD007B43W
VFD015B43W
VFD022B43W
VFD037B43W
VFD055B43W
VFD075B43W
VFD110B43W
VFD150B43W
VFD185B43W
VFD220B43W
VFD300B43W
VFD370B43W
VFD450B43W
VFD550B43W
VFD750B43W
VFD900B43W
VFD1100B43W
VFD1320B43W
VFD1600B43W
VFD1850B43W
VFD007B23A
VFD015B23A
VFD022B23B
VFD037B23A
VFD055B23A
VFD075B23A
VFD110B23A
VFD150B23A
VFD185B23A
VFD220B23A
VFD300B23A
VFD370B23A
VFD002E21A
VFD004E21A
VFD007E21A
VFD015E21A
VFD022E21A
VFD004E43A
VFD007E43A
VFD015E43A
VFD022E43A
VFD037E43A
VFD055E43A
VFD075E43A
VFD110E43A
VFD150E43A
VFD185E43A
VFD220E43A
VFD002E21T
VFD004E21T
VFD007E21T
VFD004E43T
VFD007E43T
VFD015E43T
VFD022E43A-M
VFD037E43A-M
VFD055E43A-M
VFD075E43A-M
VFD110E43A-M
VFD150E43A-M
VFD185E43A-M
VFD220E43A-M
VFD002EL21A
VFD004EL21A
VFD007EL21A
VFD015EL21A
VFD022EL21A
VFD004EL43A
VFD007EL43A
VFD015EL43A
VFD022EL43A
VFD037EL43A
VFD004CB21A-20
VFD007CB21A-20
VFD015CB21A-20
VFD022CB21A-20
VFD007CB43A-20
VFD015CB43A-20
VFD022CB43A-20
VFD037CB43A-20
VFD040CB43A-20
VFD055CB43A-20
VFD075CB43A-20
VFD007C43A
VFD015C43A
VFD022C43A
VFD037C43A
VFD040C43A
VFD055C43A
VFD075C43A
VFD110C43A
VFD150C43A
VFD185C43A
VFD220C43A
VFD300C43A
VFD370C43A
VFD370C43S
VFD450C43A
VFD450C43S
VFD550C43A
VFD750C43A
VFD900C43A
VFD1100C43A
VFD004S11A
VFD007S11A
VFD002S23A
VFD004S23A
VFD007S23A
VFD015S23D
VFD022S23D
VFD002E11T
VFD004E11T
VFD007E11A
VFD002E23T
VFD004E23T
VFD007E23T
VFD015E23T
VFD002E23A
VFD004E23A
VFD007E23A
VFD015E23A
VFD022E23A
VFD037E23A
VFD055E23A
VFD075E23A
VFD110E23A
VFD150E23A
VFD002E11P
VFD004E11P
VFD002E21P
VFD004E21P
VFD007E21P
VFD002E23P
VFD004E23P
VFD007E23P
VFD015E23P
VFD004E43P
VFD007E43P
VFD015E43P
VFD002E11C
VFD004E11C
VFD007E11C
VFD002E21C
VFD004E21C
VFD007E21C
VFD015E21C
VFD022E21C
VFD002E23C
VFD004E23C
VFD007E23C
VFD015E23C
VFD022E23C
VFD037E23C
VFD055E23C
VFD075E23C
VFD004E43C
VFD007E43C
VFD015E43C
VFD022E43C
VFD037E43C
VFD055E43C
VFD075E43C
VFD110E43C
VFD004CB23A-20
VFD007CB23A-20
VFD015CB23A-20
VFD022CB23A-20
VFD037CB23A-20
VFD004CB21A-21M
VFD007CB21A-21M
VFD015CB21A-21M
VFD022CB21A-21M
VFD007CB43A-21M
VFD015CB43A-21M
VFD022CB43A-21M
VFD037CB43A-21M
VFD040CB43A-21M
VFD055CB43A-21M
VFD075CB43A-21M
信号线与动力线必须分别放置在不同的金属管道或者金属软管内部:连接PLC和变频器的信号线如果不放置在金属管道内,极易受到变频器和外部设备的干扰;
同时由于变频器无内置的电抗器,所以变频器的输入和输出级动力线对外部会产生极强的干扰,因此放置信号线的金属管或金属软管一直要延伸到变频器的控制端子处,以保证信号线与动力线的彻底分开。
1) 模拟量控制信号线应使用双股绞合屏蔽线,电线规格为0.75mm2。在接线时一定要注意,电缆剥线要尽可能的短(5-7mm左右),同时对剥线以后的屏蔽层要用绝缘胶布包起来,以防止屏蔽线与其它设备接触引入干扰。
2) 为了提高接线的简易性和可靠性,推荐信号线上使用压线棒端子。
变频器的运行和相关参数的设置:
变频器的设定参数多,每个参数均有一定的选择范围,使用中常常遇到因个别参数设置不当,导致变频器不能正常工作的现象。
控制方式:即速度控制、转距控制、PID控制或其他方式。采取控制方式后,一般要根据控制精度,需要进行静态或动态辨识。
最低运行频率:即电机运行的最小转速,电机在低转速下运行时,其散热性能很差,电机长时间运行在低转速下,会导致电机烧毁。而且低速时,其电缆中的电流也会增大,也会导致电缆发热。
最高运行频率:一般的变频器最大频率到60Hz,有的甚至到400 Hz,高频率将使电机高速运转,这对普通电机来说,其轴承不能长时间的超额定转速运行,电机的转子是否能承受这样的离心力。
载波频率:载波频率设置的越高其高次谐波分量越大,这和电缆的长度,电机发热,电缆发热变频器发热等因素是密切相关的。
电机参数:变频器在参数中设定电机的功率、电流、电压、转速、最大频率,这些参数可以从电机铭牌中直接得到。
跳频:在某个频率点上,有可能会发生共振现象,特别在整个装置比较高时;在控制压缩机时,要避免压缩机的喘振点。
常见故障分析:
1) 过流故障:过流故障可分为加速、减速、恒速过电流。其可能是由于变频器的加减速时间太短、负载发生突变、负荷分配不均,输出短路等原因引起的。
这时一般可通过延长加减速时间、减少负荷的突变、外加能耗制动元件、进行负荷分配设计、对线路进行检查。如果断开负载变频器还是过流故障,说明变频器逆变电路已环,需要更换变频器。
2) 过载故障:过载故障包括变频过载和电机过载。其可能是加速时间太短,电网电压太低、负载过重等原因引起的。一般可通过延长加速时间、延长制动时间、检查电网电压等。
负载过重,所选的电机和变频器不能拖动该负载,也可能是由于机械润滑不好引起。如前者则必须更换大功率的电机和变频器;如后者则要对生产机械进行检修。
3) 欠压:说明变频器电源输入部分有问题,需检查后才可以运行。
小结:
1) 总之,在设计、安装、使用变频器时一定要遵从变频器使用说明书的指导。
2) 各电气设计人员,现场电气调试人员可以在此基础上完善此变频器参考。
![](http://img3.makepolo.cn/img3/000/000/_14077186502636.jpg)
![](http://img3.makepolo.cn/img3/000/000/_14077186539434.jpg)
![](http://img3.makepolo.cn/img3/000/000/_14077186544333.jpg)
![](http://img3.makepolo.cn/img3/000/000/_14077186705413.jpg)