MK2P | AC6 | AC12 | AC24 | AC50 | AC100/110 | AC200/220 |
DC6 | DC12 | DC24 | DC48 | DC100 | ||
MK2ZP | AC24 | AC100/110 | AC200/220 | |||
DC12 | DC24 | DC48 | DC100 | |||
MK2P-DO | DC6 | DC12 | ||||
DC24 | DC48 | DC100 | ||||
MK2PA | AC100/110 | AC200/220 | ||||
DC24 | ||||||
DC48 | DC100 | |||||
MK2PN | AC6 | AC12 | AC24 | AC50 | AC100/110 | AC200/220 |
DC6 | DC12 | DC24 | DC48 | DC100 | ||
- | - | |||||
MK2P-2 | AC6 | AC24 | AC50 | |||
AC100/110 | AC200/220 | |||||
DC6 | ||||||
DC12 | DC24 | DC48 | DC100 | |||
- | - | |||||
MK2ZP-2 | AC24 | AC200/220 | ||||
AC100/110 | ||||||
DC24 | DC100 | |||||
- | - |
MK3P | AC6 | AC12 | AC24 | AC50 | AC100/110 | AC200/220 |
DC6 | DC12 | DC24 | DC48 | DC100/110 | ||
MK3ZP | AC6 | |||||
AC12 | ||||||
AC24 | AC50 | AC100/110 | AC200/220 | |||
DC6 | DC12 | |||||
DC24 | DC48 | DC100 | ||||
MK3P-DO | DC12 | DC24 | DC48 | |||
DC100 | ||||||
MK3PA | AC24 | AC100/110 | AC200/220 | |||
DC24 | DC100 | |||||
DC48 | ||||||
MK3PN | AC6 | AC12 | AC24 | AC50 | AC100/110 | AC200/220 |
DC12 | DC24 | DC48 | DC100 | |||
MK3LP | AC12 | AC24 | ||||
AC100/110 | AC200/220 | |||||
DC24 | DC48 | DC100 | ||||
MK3P-2 | AC6 | AC24 | AC100/110 | AC200/220 | ||
AC50 | ||||||
DC12 | DC24 | DC48 | DC100 | |||
MK3P-5 | AC12 | |||||
AC24 | AC100/110 | AC200/220 | ||||
DC6 | DC12 | DC48 | DC100 | |||
DC24 | ||||||
MK3ZP-2 | AC24 | |||||
AC100/110 | AC200/220 | |||||
DC6 | DC12 | DC48 | ||||
DC24 | DC100 | |||||
MK3ZP-5 | AC24 | AC100/110 | AC200/220 | DC24 |
MK2P-US | AC100 | MK3P-US | AC200 |
AC200 | |||
DC24 | |||
MK2P2-US | DC12 | MK3P2-US | AC200/(220) |
DC24 | |||
MK3P5-US | AC24 | ||
AC200/(220) | |||
DC24 |
关于国际标准认证型,请参见catalog。
操作线圈 MK2 (P、P-2)、MK3 (P、P-2、P-5)、MK2ZP (-2)、MK□PA、MK□P-DO404 | 360 | 5.3 | 0.028 | 0.41 | 80%以下 | 30%以上 | 110% | 约1.9~ 约2.2 (60Hz) |
202 | 180 | 21.5 | 0.115 | 0.165 | ||||
98 | 88 | 91 | 0.422 | 0.678 | ||||
43.6 | 39 | 420 | 1.95 | 3.2 | ||||
22.4/24.7 | 19/21 | 1,620 | 9.0 | 13.2 | 约1.9~约2.4 (60Hz) | |||
11.7/12.9 | 10/11 | 7,100 | 33.9 | 49.6 | ||||
255 | 23.5 | 0.14 | 0.23 | 10%以上 | 约1.5 | |||
126 | 95 | 0.56 | 0.87 | |||||
56 | 430 | 2.82 | 4046 | |||||
29.5 | 1,630 | 10.99 | 16.52 | |||||
14.7 | 6,800 | 41.46 | 66.34 |
500 | 445 | 3.8 | 约2.8(60Hz) |
258 | 230 | 16.2 | |
130 | 116 | 62 | |
63 | 56 | 280 | |
27.1/29.8 | 23.1/25.4 | 1,300 | 约2.3~约2.8 (60Hz) |
13.6/14.9 | 11.5/12.7 | 5,900 | |
302 | 19.9 | 约1.9 | |
156 | 77 | ||
79 | 303 | ||
39 | 1,230 | ||
18.9 | 5,300 |
420 | 375 | 5.3 | 约2.2~约2.7 (60Hz) |
220 | 195 | 21.5 | |
110 | 100 | 91 | |
60 | 53 | 420 | |
22.4/24.7 | 19/21 | 1,620 | 约1.9~约2.4 (60Hz) |
11.7/12.9 | 10/11 | 7,100 | |
275 | 23.5 | 约1.6~约2.3 | |
146 | 95 | ||
71 | 430 | ||
48 | 1,630 | ||
14.7 | 6,800 | 约1.5 |
注1. 额定电流、线圈电阻值指的是线圈温度为+23℃时的值。公差为AC额定电流+15%、-20%、DC线圈电阻±15%。
2. AC线圈电阻、线圈电感的值为参考值。
3. 动作特性指的是线圈温度为+23℃时的值。
4. 最大许容电压指的是在环境温度为+23℃时继电器线圈操作电源的电压容许变化范围内的最大值。不是连续容许。
* 为4额定规格。
单 | |||
Ag | |||
AC220V 5A DC24V 3A | AC220V 2A DC24V 2.5A | AC220V 3A DC24V 2A | AC220V 1.2A DC24V 1.5A |
5A | 3A | ||
AC250V DC250V | AC250V DC250V | ||
5A | 5A | 3A | 3A |
1,100VA 72W | 440VA 60W | 660VA 48W | 260VA 35W |
单 | 双 | ||
Ag、Ni | Ag | ||
AC220V 3A DC24V 2A | AC220V 1.2A DC24V 1.5A | AC220V 5A DC24V 3A | AC220V 3A DC24V 1.8A |
3A | 5A | ||
AC250V DC250V | AC250V DC250V | ||
3A | 3A | 5A | 5A |
660VA 48W | 260VA 35W | 1,100VA 72W | 660VA 42W |
-10~+40℃(无结冰、结露) |
5~85%RH |
25mΩ以下 | 50mΩ以下 |
AC用20ms以下、DC用30ms以下 | |
20ms以下(*4 40ms以下) | |
18,000次/h | |
1,800次/h | |
100MΩ以上 | |
AC2,000V 50/60Hz 1min | |
AC1,000V 50/60Hz 1min | |
AC1,500V 50/60Hz 1min | |
AC1,000V 50/60Hz 1min | |
10~55~10Hz 单振幅0.75mm(双振幅1.5mm) | |
10~55~10Hz 单振幅0.5mm(双振幅1.0mm) | |
1,000m/s2 | |
100m/s2 | |
500万次以上(开关频率18,000次/h) | |
50万次以上(额定负载、开关频率1,800次/h) | |
DC1V 100μA | DC1V 10mA |
约85克 |
注: 上述值为初始值。
*1. 测量条件:依据DC5V 1A电压下降法。
*2. 测量条件:外加额定操作电压时,不包括接点跳动。
环境温度条件:+23℃
*3. 测量条件:用DC500V绝缘电阻计测量与耐电压项目中相同的部位。
*4. 为二极管内置型的值。
*5. 环境温度条件:+23℃
*6. 此值为开关频率60次/min时的值。