| ontrol interface unit IDENTControl Compact with PROFIBUS DP interface |
| Number of read/write heads | max. 2 alternatively 1 read/write head and 1 trigger sensor | |
| UL File Number | E87056 | |
| LEDs 1, 2 | Status indicator for read/write heads green: command at read/write head active yellow: approx. 1 second long, if command was successfully executed | |
| LEDs CH1, CH2 | green: read head detected red: Configuration error | |
| LED PWR/ERR | green: power on red: Hardware fault | |
| Rotary switch | Address setting 00 ... 7E, FF (hexadecimal) BUS Address (high nibble): 0 ... 7, F BUS Address (low nibble): 0 ... F | |
| Rated operating voltage | 20 ... 30 V DC , PELV | |
| Ripple | ≤ 10 % at 30 V DC | |
| Current consumption | ≤ 4 A incl. read/write heads | |
| Power consumption | 2 W Without read/write heads | |
| Galvanic isolation | basic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff | |
| Interface type | PROFIBUS | |
| Physical | RS-485 | |
| Protocol | PROFIBUS DP acc. to EN 50170 | |
| Interface type | Diagnostic Interface | |
| Physical | RS 232 | |
| Protocol | ASCII | |
| Transfer rate | 38.4 kBit/s | |
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61000-6-2:2005, EN 61000-6-4:2007 | |
| Degree of protection | IEC 60529:2001 | |
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Climatic conditions | air humidity max. 96 % Salt spray resistant to EN 60068-2-52 | |
| Shock and impact resistance | Oscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6 Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27 | |
| Degree of protection | IP67 | |
| Connection | Read/write heads: shielded, 4-pin, M12 connector Power supply: M12 connector Protective earth: M4 earthing screw Diagnostic RS 232: M12 connector PROFIBUS: M12 connector, B-coded | |
| Material | ||
| Housing | Powder coated zinc | |
| Installation | screw fixing | |
| Mass | approx. 500 g | |