Emerson & Cuming
a pision of National Starch and Chemical
Company
Applications Engineering
Group
46 Manning Road
Billerica, Massachusetts
01821
Phone: 978-436-9700
Fax: 978-436-9701
品牌:美国乐泰Emerson & Cuming
型号:XE-1218
三星认证、指定型号,设计产品三星手机、摄像头模组及所有含有BGA芯片的产品
XE 1218
Fast Flow, Reworkable,
Capillary Underfill
Preliminary Technical
Data
Material Properties
Color Black
Viscosity @ R.T. 1,400 cps
Enthalpy, ΔH: 350 J/g
Storage Modulus @ 25°C (via DMA): 325 MPa
Process Information
Flow time 5 seconds
(200 um gap, 80°C
preheat temp, 1 cm flow)
Work life at 25ºC 7 days
Work life at 40ºC 24 hours
Cure schedule (time at temperature):
110 C
10 minutes
100 C 22 minutes
Shelf life: 6 months @ -20°C
Instructions for use:
XE 1218 flows under the area array device by capillary action. While it is
not essential, the underfill area should be cleaned of contaminants and
obstructions to optimize the speed and quality of the
underfill process.
Preheat assembly to between 80ºC. Dispense a bead of the underfill using a
syringe fitted with a 21 gauge needle on one (line) or two sides (L-shape) of
the device perimeter. Syringe tip heating is not needed, but can be used. Very large devices
may require multiple beads of underfill, but for most no second or ‘fillet
pass’ is required. Because of its low viscosity and outstanding wetting characteristics,
XE 1218 is designed to ‘self-fillet’ the opposite sides of the device.
Rework Procedure:
If assembly is defective after cure, XE 1218 allows for the component to
be easily reworked. The preferred method is with a non-contact rework machine
which minimizes potential damage to the PCB and soldermask.
Remove the component from the substrate by using local application of heat
onto the component. The recommended heat profile is an identical profile used
during initial assembly. Once the solder has reached temperatures above it’s
reflow temperatures, lift the device off by using a slight twisting motion.
The site then should be cleaned, removing any excess underfill and solder
remaining on the PCB site. Again, a non-contact, vacuum method is preferred.
Total time required for component removal is about 5-7 minutes.