SH 220 series
current ratings from 6 to 40A
good common mode and differential mode attenuation
good low-frequency attenuation optional medical versions (B type)
Specification
1. Maximum operating voltage: 250VAC
2. Operating frequency: 50/60Hz
3. Hipot test voltage(one minute):
PN---E: 2000VAC
P---N: 1760VDC
4. Maximum Leakage current:
Line to Ground at 250VAC 50Hz:
0.3mA(6~10A); 0.5mA(20~40A); 0.002mA(B types)
5. Operating temperature : -25~+85 C
6. Min. Resistance:
Line to Ground at 500VDC: 200M | C
|