![](//img11.makepolo.cn/images/formals/img/product/874/823/4_c6ba9b8f02837559b6b46ab9c48f1fe7.jpg)
![](//img12.makepolo.cn/images/formals/img/product/368/25/4_f78836c9e7b2d91b62eaeef60cc1d40a.jpg)
![](//img11.makepolo.cn/images/formals/img/product/94/477/4_f676a20575c13f9e36d256a74eb22cb8.jpg)
![](//img11.makepolo.cn/images/formals/img/product/677/343/4_b26d43bfad28f01dbd38e25efcd91e48.jpg)
![](//img11.makepolo.cn/images/formals/img/product/292/812/4_2834ca645212384dae8ab9a8c09aa891.jpg)
![](//img12.makepolo.cn/images/formals/img/product/3/499/4_5dc37723cc08611a5b187a1fa4877108.jpg)
![](//img12.makepolo.cn/images/formals/img/product/246/795/4_7df6c283a072efc8a92edff0267ab968.jpg)
![](//img12.makepolo.cn/images/formals/img/product/794/869/4_070270c55b0b98443bf24aa9710e4373.jpg)
![](//img11.makepolo.cn/images/formals/img/product/556/12/4_dceca41c590f4e670b66472cecee2054.jpg)
![](//img12.makepolo.cn/images/formals/img/product/764/266/4_976c85da427afe31b075df30e40f14b3.jpg)
![](//img11.makepolo.cn/images/formals/img/product/352/978/4_14e89c2a4d6ef7f7b2a2f0db04db9698.jpg)
![](//img11.makepolo.cn/images/formals/img/product/23/283/4_debff34b0b74b180f3d64cc4a55c7b25.jpg)
一、适用范围:
FCS系列矿用电缆冷补器(和电缆冷补胶配套使用)适用于修补10千伏及以下各种电缆。电缆终端、中间连接及电缆运行过程中因受拖、挤、砸、冲击或炮崩等原因造成电缆护套损破皆可用此冷补器进行修补。
二、安装
1、待修补电缆停止送电,清除待修补电缆破损处及周围表面上的污垢和煤粉,检查护套破损部位情况。
2、修补电缆时,按图1及表1(参考尺寸)规定切除电缆破损护套层,将修补段削成锥形,打毛,保持洁净。
3、在修补段两端锥形面上部用自粘胶带缠绕4圈左右,以便增加修补的护套层厚度。
4、将修补段电缆尽量拉直,置于水平位置,根据修补电缆的外径大小,选取电缆冷补器具。
5、拧开电缆冷补器上的元宝螺帽,翻开带有注胶口一方,将需修补的电缆段放于冷补器中,固定好后合上冷补器,拧紧元宝螺帽,装好如图3所示。
6、将配好的电缆冷补胶徐徐的倒入注胶口,因本冷补器呈透明状,可清楚的看到冷补胶的填充状况,冷补器内的气体通过注胶口两边的排气孔,排出器具外,当冷补器腔内充满胶料,且注胶口两侧胶液快溢出时,停止浇注。如胶液液面有下降,应当立即补充胶料。
7、冷补胶注满后,等到半小时后,松开冷补器的元宝螺帽,从电缆上取出冷补器(胶料不会和冷补器粘在一起)。取下的冷补器可重新利用。
三、注意事项:
1、橡套电缆在修补过程中一定要停止送电。
2、修补电缆时应尽量选择干燥的地方,避免水份和混合物的影响。
3、刚修好的电缆初始强度不太高,应避免强烈弯曲、挤压,但可以送电运行。