高频噪声模拟试验器 INS-AX2-220/250/420/450
GENERAL
The INS-AX2 series simulators are the advanced version of the conventional manually operated INS-4020/4040 simulators, maintaining the identical interference signal characteristics while offering a new level of ease of use.
FEATURES
SPECIFICATIONS
Item | Model | ||
INS-AX2-220/250 | INS-AX2-420/450 | ||
Pulse output voltage | 0.01 ~ 2.00kV±10% at 0.01kV step | 0.01 ~ 4.00kV±10% at 0.01kV step | |
±0.04kV allowance for <0.1kV setting When the output is terminated by the internal resistors. | |||
Output polarity | Positive or negative | ||
Pulse | Pulse width | 50, 100, 200, 400, 500, 800, 1000ns ±10%, 10ns±3ns | |
Rise time | <1ns | ||
Output impedance | 50 ohm system (53.5 ohm) | ||
Pulse repetition mode | Variable | 10ms ~ 999ms±10% | 16ms ~ 999ms±10% |
Phase | Injection phase angle 0 to 360 degrees±10 degrees EUT power supply:>AC90V, 50/60Hz±10% | ||
1 shot | Single pulse generation, each time the 1 SHOT button is pressed. Synchronized output with phase angle setting in PHASE mode | ||
Power capacity of EUT | INS-AX2-220: Single phase AC240V/DC65V 20A INS-AX2-250: 3-phase (4-wire) AC500V/DC250V 50A 50/60Hz±10% | NS-AX2-420: Single phase AC240V/DC65V 20A INS-AX2-450: 3-phase (4-wire) AC500V/DC250V 50A 50/60Hz±10% | |
Power supply | AC 100V~240V±10%, 50/60Hz±10% | ||
Power consumption | 110VA | ||
Operating temperature and humidity range | 15 ~ 35°C, 25 ~ 75% (No dewing shall occur.) | ||
Dimensions | W 430 x H 350 x D 470mm, projection excluded | ||
Weight | INS-AX2-220: Approx. 30Kg INS-AX2-250: Approx. 38Kg | INS-AX2-420: Approx. 30Kg INS-AX2-450: Approx. 38Kg | |
Mercury relay unit | Model: 04-00014A | Model: 04-00015A |
TRIANGULAR PULSE ADDITION (Factory Option)
Parameters | Specifications | |
Output pulse waveform | Triangular pulse | |
Pulse output voltage | 2kV (220/250) and 4kV (420/450) max (when the output is terminated by the internal resistors) | |
Output polarity | Positive or negative | |
Pulse | Duration | 1μs±30% |
Rise time | <40 ns |
STANDARD ACCESSORIES
INS-AX2-220/420 | INS-AX2-250/450 |
Outlet panel (Single phase terminal block type) Model:18-00067A AC240VDV65V20A max | Outlet panel (3-phase terminal block type) Model:18-00068A AC500VDV250V50A max |
Power cable Remote control software (CD-ROM) Model: 14-00033A Optic-RS232C converter Model 07-00017A Optical cable (5m) D-sub conversion connector Instruction manual (for the simulator and remote control software) |
The INS-AX2 series simulators are the advanced version of the conventional manually operated INS-4020/4040 simulators, maintaining the identical interference signal characteristics while offering a new level of ease of use.
INS-AX2-220/250 : 0.01 ~ 2.00kV±10% at 0.01kV step Pulse output voltage
INS-AX2-420/450 : 0.01 ~ 4.00kV±10% at 0.01kV step Pulse output voltage
An innovative,motor driven coaxial switch mechanism eliminates the need to manually plug and unplug coaxial connectors, allowing a preset test sequence to be carried out seamlessly including pulse width and coupling mode changes, automatic voltage ramp and others.
As well as manual control, the simulator can be remote-controlled through a fiber optic computer interface. A Windows control software package is supplied as an included accessory.
Floating output
8 pulse widths installed: 10ns, 50ns, 100ns, 200ns, 400ns, 500ns, 800ns and 1000ns
Internal switchable terminators
Easily changeable and safety-interlocked outlet panel (EUT interface)
3 channels EUT fail input
SPECIFICATIONS
Item | Model | ||
INS-AX2-220/250 | INS-AX2-420/450 | ||
Pulse output voltage | 0.01 ~ 2.00kV±10% at 0.01kV step | 0.01 ~ 4.00kV±10% at 0.01kV step | |
±0.04kV allowance for <0.1kV setting | |||
Output polarity | Positive or negative | ||
Pulse | Pulse width | 50, 100, 200, 400, 500, 800, 1000ns ±10%, 10ns±3ns | |
Rise time | <1ns | ||
Output impedance | 50 ohm system (53.5 ohm) | ||
Pulse repetition mode | Variable | 10ms ~ 999ms±10% | 16ms ~ 999ms±10% |
Phase | Injection phase angle 0 to 360 degrees±10 degrees | ||
1 shot | Single pulse generation, each time the 1 SHOT button is pressed. | ||
Power capacity of EUT | INS-AX2-220: | NS-AX2-420: | |
Power supply | AC 100V~240V±10%, 50/60Hz±10% | ||
Power consumption | 110VA | ||
Operating temperature and humidity range | 15 ~ 35°C, 25 ~ 75% (No dewing shall occur.) | ||
Dimensions | W 430 x H 350 x D 470mm, projection excluded | ||
Weight | INS-AX2-220: Approx. 30Kg | INS-AX2-420: Approx. 30Kg | |
Mercury relay unit | Model: 04-00014A | Model: 04-00015A |
» Standard included accessories
STANDARD ACCESSORIES
INS-AX2-220/420 | INS-AX2-250/450 |
Outlet panel (Single phase terminal block type) Model:18-00067A AC240VDV65V20A max | Outlet panel (3-phase terminal block type) Model:18-00068A AC500VDV250V50A max |
Power cable |
» Recommended Options, Services and Accessories
TRIANGULAR PULSE ADDITION (Factory Option)
Parameters | Specifications | |
Output pulse waveform | Triangular pulse | |
Pulse output voltage | 2kV (220/250) and 4kV (420/450) max (when the output is terminated by the internal resistors) | |
Output polarity | Positive or negative | |
Pulse | Duration | 1μs±30% |
Rise time | <40 ns |