电站用穿墙套管适用于35kV及以下电压等级的电站、变电所配电装置及电器设备中,供导线(母线)穿过接地隔板,墙壁及封闭配电机构中作为绝缘支持和外部导线(母线)连接用。 High pressure wall bushing of power station is suitable for up to and including 35 kv voltage grade of power plant, substation, power distribution equipment and electrical equipment, For lead (bus) through the ground plate, Walls and closed distribution agencies as support and external insulation wire (bus) in connection with. (二)产品分类Product categories 电站用高压穿墙套管分为户内和户外两大类,有铜导体、铝导体及不带导体的母线式穿墙套管三种结构,并有普通型和耐污型两大类产品。 Wall bushing pided into two big series: indoor and outdoor,Three kinds of structure with copper conductor and aluminum conductor and busbar wall bushing without a conductor,And have a regular and fouling resistance type two categories of products. (三)产品制造依据Product manufacturing basis 高压穿墙套管性能符合GB12944.1-91《高压穿墙套管技术条件》、GB12944.2《高压穿墙套管尺寸与特性》的规定。 High pressure wall bushing Performance conforms to GB12944.1-91 High pressure wall bushing technology conditions and GB12944.2 High pressure wall bushing size and characteristics. 二、主要技术参数 Main technical parameters (一)使用环境 1.户内套管Indoor bushing a)环境温度不高于+40℃,不低于-40℃; The environment temperature is ≤ + 40 ℃, ≥- 40 ℃ b)海拔不超过1000m;The altitude does not exceed 1000 m; c)相对湿度月平均不大于90%; The average ≤ 90% relative humidity; d)周围空气应不受腐蚀性和可燃气体、水蒸汽等明显污秽; Ambient air should not be obvious, such as corrosive and flammable gas, water vapor and filth. e)无经常性的剧烈振动。No recurrent severe vibration. 2.户外套管Outdoor bushing a)环境温度不高于+40℃,不低于-40℃; The environment temperature is ≤ + 40 ℃, ≥- 40 ℃ b)海拔不超过1000m;The altitude does not exceed 1000 m; c)风速不大于34m/s;Wind speed is not more than 34 m/s; d)产品的使用环境的空气污秽程度,按GB5582分为0、Ⅰ、Ⅱ、Ⅲ、Ⅳ等五级; Products using the environment air polluted degree, accord to GB5582 into 0, Ⅰ, Ⅱ, Ⅲ, Ⅳ; e)无经常性的剧烈振动。No recurrent severe vibration. (二)型号说明 Model specification CWC—户外-户内穿墙瓷套管Indoor-outdoor wall porcelain bushing;C—抗弯破坏负荷等级Bending failure load level,12kN(加强型enhanced)。 (三)穿墙套管技术参数Wall Bushing Technical parameters No. Device name 35kV AC HV Aluminum Conductor Wall Bushing 1 Type CWWL-40.5/2500A-4 (四)特点及结构简介 Characteristics and structure 套管由瓷套、安装法兰及导电部分装配而成,母线穿墙套管不带导电部分。瓷套与法兰固定方式,除35kV高原型以及部分耐污型产品采用机械卡装外,其余均用水泥胶合剂胶装;铜质电杆采用定心垫圈和螺母固定,铜、铝导电排采用定心垫圈和开口销固定。对母线穿墙套管所带安装用夹板,出厂时未加工开口尺寸,以便用户根据实际选用的母线规格型式自行确定开口尺寸。瓷件表面一般上棕釉。安装法兰一般采用灰铸铁,但电流等级为1500A及以上产品的法兰、端帽及定心垫圈采用硅铝合金,以降低套管在长期工作下的发热温度。各种黑色金属附件表面涂灰磁漆。
CWB—户外-户内圆导杆穿墙瓷套管Indoor-outdoor circular guide wall porcelain bushing;
CWL—户外-户内铝导体穿墙套管Indoor-outdoor aluminum conductor wall bushing;
CWW—户外-户内耐污型铜导体穿墙套管Indoor-outdoor antifouling type copper conductor wall bushing;
CWWL—户外-户内耐污型铝导体穿墙套管Indoor-outdoor antifouling type aluminum conductor wall bushing;
为了提高套管的起始电晕,对20和35kV套管在结构上采取均压措施,将靠近法兰部位的瓷套及两边的伞(棱)适当加大、加厚,在瓷件焙烧前于瓷套内腔和法兰附近以及靠近法兰的上一个伞(棱)上均匀涂上一层半导体釉,经焙烧后使半导体釉牢固地结合在瓷壁上,并通过接触片使导体与瓷壁短路,这样就大大改善了电场分布,防止套管内腔发生放电,提高滑闪放电电压。以往对20和30kV套管内腔和法兰处采用喷铝层来改善电场分布,运行证明铝层易于剥落,往往不起作用,改用上半导体釉后克服了喷铝的缺点。