露明纳自动喷枪ST系列: 标准纤细、结构精密、用途广泛。
ST-6系列的喷枪采用雾化用空气分离方式,可以在低压下操作喷出粗糙的雾化粒子。
Before using the Lumina Automatic Spray Gun ST-6/ST-6R for the first time, this manual should
first be thoroughly read in order to get full use of this spray gun's capabilities and help ensure safe
use. Afterwards, keep this manual readily at hand should further reference be necessary
如需更多资料,请咨询贺经理13903074427(WX同号)、小陈020-84559953 pycs@jaeger.com.cn。
1. Piston potion Disassembling (parts #4 - #13)
• Turn #13 Liquid Volume Adjuster counterclockwise to remove it, being careful not to let #9 Piston Spring
pop out.
• Pull #19 Piston Set straight out, or if this is difficult, apply air from an air duster into the Air inlet while
covering the back portion with your hand so that #19 Piston Set does not fly out, and then it can be easily
taken out.
Liquid Adjustment
ST-6/ST-6R manual No.S0931
2. Air Cap, Nozzle Disassembling (parts #1 - #2)
• Turn #1 Air Cap's Ring Nut counterclockwise to remove #1 Air Cap straight.
• Turn #2 Liquid Nozzle counterclockwise with #20 Spanner (specially designed) to remove it. Do not use plier
which damages the nozzle.
• To reassemble, reverse the order of the above steps. Fully tighten #2 Liquid Nozzle with #20 Spanner,
otherwise, intermittent spraying may be caused by intrusion of air into the liquid passage through a gap.