Nominal Voltage 3 phase, 3 wire + ground | 380 VAC (operating range 342 - 418 VAC) 415 VAC (operating range 373 - 456 VAC) 440 VAC (operating range 396 - 484 VAC) 480 VAC (operating range 432 - 528 VAC) |
Frequency | 50 Hz, 60 Hz |
Power Factor | Greater than 92% at maximum power |
Operating Temperature | 0°C to 50°C |
Storage Temperature | -25°C to +85°C |
Air Cooling | Front and rear intake, top exhaust |
Power | Input Phases | Size (H" x W" x D") | Weight | |
100 kW 150 kW 200 kW 300 kW 400 kW 450 kW 600 kW | 3? 3? 3? 3? 3? 3? 3? | 62.5 x 48 x 31.5 in (158.8 x 121.9 x 80.0 cm) 62.5 x 48 x 31.5 in (158.8 x 121.9 x 80.0 cm) 62.5 x 96 x 31.5 in (158.8 x 243.8 x 80.0 cm) 62.5 x 96 x 31.5 in (158.8 x 243.8 x 80.0 cm) 62.5 x 192 x 31.5 in (158.8 x 487.7 x 80.0 cm) 62.5 x 144 x 31.5 in (158.8 x 365.8 x 80.0 cm) 62.5 x 192 x 31.5 in (158.8 x 487.7 x 80.0 cm) | 1600 lbs (725.8 kg) 2100 lbs (952.5 kg) 3200 lbs (1451.5 kg) 4200 lbs (1905.1 kg) 6400 lbs (2903.0 kg) 6300 lbs (2857.6 kg) 8400 lbs (3810.2 kg) | |
Ripple | See Model Charts |
Line Regulation | Voltage Mode: ± 0.004% of full scale Current Mode: ± 0.02% of full scale |
Load Regulation | Voltage Mode: ± 0.01% of full scale Current Mode: ± 0.04% of full scale |
Load Transient Response | 2 ms to recover within ±1% of regulated output with a 50% to 100% or 100% to 50% step load change |
Efficiency | ≥ 90%; See Model Charts |
Stability | ± 0.10% for 8 hrs. after 30 min. warmup |
Maximum Slew Rate | Standard Models: 100 ms for an output voltage change from 0 to 63%, 100 ms for an output current change from 0 to 63%. With High-Slew Rate Option |
Bandwidth | Standard Models: 3 Hz with remote analog voltage programming, 2 Hz with remote analog current programming. With High Slew Rate Option: |
Isolation | Maximum input voltage to ground: ±2500 Vac User inputs and outputs: referenced to Earth ground For models less than or equal to 1000 Vdc: For models greater than 1000 Vdc: |
Voltage Set Point | Current Set Point | OVT Set Point | OCT Set Point | |
Remote Analog Programming Accuracy | ± 0.50% | ± 0.75% | ± 0.50% | ± 0.75% |
Digital Programming Accuracy | ± 0.50% | ± 0.75% | ± 0.50% | ± 0.75% |
Remote Analog Programming Levels | 0 - 10.0 Vdc | 0 - 10.0 Vdc | 0 - 10.0 Vdc | 0 - 10.0 Vdc |
Output Voltage | Output Current | |||
Remote Analog Monitoring Accuracy | ± 0.50% | ± 0.75% | ||
Digital Monitoring Accuracy | ± 0.50% | ± 0.75% | ||
Remote Analog Monitoring Levels | 0 - 10.0 V | 0 - 10.0 V | ||
Remote Sense Limits | 3% maximum voltage drop from output to load |
Period Programming Limits | Minimum period: 10 msec Maximum Period: 9997 sec or 2.77 hours |
Digital control inputs and outputs limits | Input voltage: 0 to 5 Vdc, 10K input impedance; Output voltage: 0 to 5 Vdc, 5 mA drive capacity 5 V supply: 25 mA. |