| Nominal Voltage 3 phase, 3 wire + ground | 380 VAC (operating range 342 - 418 VAC) 415 VAC (operating range 373 - 456 VAC) 440 VAC (operating range 396 - 484 VAC) 480 VAC (operating range 432 - 528 VAC) |
| Frequency | 50 Hz, 60 Hz |
| Power Factor | Greater than 92% at maximum power |
| Operating Temperature | 0°C to 50°C |
| Storage Temperature | -25°C to +85°C |
| Air Cooling | Front and rear intake, top exhaust |
| Power | Input Phases | Size (H" x W" x D") | Weight | |
| 100 kW 150 kW 200 kW 300 kW 400 kW 450 kW 600 kW | 3? 3? 3? 3? 3? 3? 3? | 62.5 x 48 x 31.5 in (158.8 x 121.9 x 80.0 cm) 62.5 x 48 x 31.5 in (158.8 x 121.9 x 80.0 cm) 62.5 x 96 x 31.5 in (158.8 x 243.8 x 80.0 cm) 62.5 x 96 x 31.5 in (158.8 x 243.8 x 80.0 cm) 62.5 x 192 x 31.5 in (158.8 x 487.7 x 80.0 cm) 62.5 x 144 x 31.5 in (158.8 x 365.8 x 80.0 cm) 62.5 x 192 x 31.5 in (158.8 x 487.7 x 80.0 cm) | 1600 lbs (725.8 kg) 2100 lbs (952.5 kg) 3200 lbs (1451.5 kg) 4200 lbs (1905.1 kg) 6400 lbs (2903.0 kg) 6300 lbs (2857.6 kg) 8400 lbs (3810.2 kg) | |
| Ripple | See Model Charts |
| Line Regulation | Voltage Mode: ± 0.004% of full scale Current Mode: ± 0.02% of full scale |
| Load Regulation | Voltage Mode: ± 0.01% of full scale Current Mode: ± 0.04% of full scale |
| Load Transient Response | 2 ms to recover within ±1% of regulated output with a 50% to 100% or 100% to 50% step load change |
| Efficiency | ≥ 90%; See Model Charts |
| Stability | ± 0.10% for 8 hrs. after 30 min. warmup |
| Maximum Slew Rate | Standard Models: 100 ms for an output voltage change from 0 to 63%, 100 ms for an output current change from 0 to 63%. With High-Slew Rate Option |
| Bandwidth | Standard Models: 3 Hz with remote analog voltage programming, 2 Hz with remote analog current programming. With High Slew Rate Option: |
| Isolation | Maximum input voltage to ground: ±2500 Vac User inputs and outputs: referenced to Earth ground For models less than or equal to 1000 Vdc: For models greater than 1000 Vdc: |
| Voltage Set Point | Current Set Point | OVT Set Point | OCT Set Point | |
| Remote Analog Programming Accuracy | ± 0.50% | ± 0.75% | ± 0.50% | ± 0.75% |
| Digital Programming Accuracy | ± 0.50% | ± 0.75% | ± 0.50% | ± 0.75% |
| Remote Analog Programming Levels | 0 - 10.0 Vdc | 0 - 10.0 Vdc | 0 - 10.0 Vdc | 0 - 10.0 Vdc |
| Output Voltage | Output Current | |||
| Remote Analog Monitoring Accuracy | ± 0.50% | ± 0.75% | ||
| Digital Monitoring Accuracy | ± 0.50% | ± 0.75% | ||
| Remote Analog Monitoring Levels | 0 - 10.0 V | 0 - 10.0 V | ||
| Remote Sense Limits | 3% maximum voltage drop from output to load |
| Period Programming Limits | Minimum period: 10 msec Maximum Period: 9997 sec or 2.77 hours |
| Digital control inputs and outputs limits | Input voltage: 0 to 5 Vdc, 10K input impedance; Output voltage: 0 to 5 Vdc, 5 mA drive capacity 5 V supply: 25 mA. |