Model Name : YM-5601BxR
2U Single Series 600 watts
● 100.0(W) x 70.0(H) x 240.0(L) mm ● Power Density 5.85 W/in³ ● Efficiency:≧ 80% at Max load of 115 ~ 230VAC ● Optional -5V Rail ● Tylersburg compliant ● RoHS compliant for all six substances
● Download |
|
| |
|
|
|
|
|
|
Input Voltage Input Frequency Input Current
Inrush Current Power Factor
Earth Leakage Current |
|
90 - 264VAC 47 - 63 Hz 10A max at 115V 5A max at 230V 115V / 230V, No damage > 0.98 at 115V / 60Hz > 0.93 at 230V / 50Hz 3.5mA max at 264V / 50Hz | |
|
|
|
Efficiency Power Density MTBF
|
|
≧ 80% at Max load of 115 ~ 230VAC 5.85 W/in³ 100 kHrs per Bellcore SR-332 ISSUE1 at 25° C ambient
| |
|
|
|
| |
|
|
Output Voltage Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Over / Undershoot Transient Response
Over Voltage Protection
Over Current Protection
Over Temperature Protection
Short Circuit Protection Remote On/Off |
|
See table See table < 500mSec maximum < 20mSec measured at 10% to 90% 16mSec / 115V < 10% max at turn on/off < 4% max piation, recovery to within 1% in 1mSec for 25%load change +3.3V:3.5V ~ 4.5V +5V:5.5V ~ 6.82V +12V:13.4V ~ 15.6V +3.3V:26.4A ~ 36A +5V:26.4A ~ 36A +12V:52.8A ~ 72A Primary & secondary protection with latch off No damage, resistance ≦ 0.01Ω On = PSON ≦ 0.8V, low Off = PSON ≧ 2.4V, high, open | |
|
| |
|
|
|
Operating Temperature Cooling Operating Humidity Storage Temperature Shock Operating Non-Operating Vibration Operating |
|
0 to 40°C rear mounted fan 85% RH, Non-condensing -20°C to +80°C 10G, 11mSec, half sine 3 axes 40G, 11mSec, half sine 3 axes 0.25G, 10 Hz to 250 Hz, 3 axes | |
|
|
|
|
Emissions
Harmonic Currents Voltage Flicker EFT/Burst Surge Conducted Immunity Safety Approvals |
|
EN55022, class B Conducted EN55022, class B Radiated EN61000-3-2, class D EN61000-3-3 EN61000-4-4, level 3 Perf Criteria B EN61000-4-5, level 3 Pref Criteria B EN61000-4-6, 10Vrms, Pref Criteria A UL/cUL60950-1, TUV, CB, CE, CCC Report | |
|
| | |
Application |
|
● |
Broadcasting |
|
● |
Industrial |
|
● |
Server |
|
● |
Storage |
|
● |
Networking |
|
● |
Workstation |
| |
Output |
Minimum Load |
Maximum Load |
Condition |
Ripple & Noise |
+3.3V |
0.5A |
24A |
+3.3V & +5V combined power ≦ 150W
Combined current +12V1 ≦ 48A
| |
50mV p-p |
+5V |
0.5A |
24A |
50mV p-p |
+12V |
3A |
48A |
120mV p-p |
-12V |
0A |
0.5A |
120mV p-p |
-5V |
0A |
0.3A |
100mV p-p |
+5VSB |
0A |
2.5A |
50mV p-p | |
|