更多产品信息可来电咨询:周先生 13524226693 QQ;155185284
Model Name : YH8451-1BxR
1U Redundant Series 450 watts
● 106.0(W) x 41.5(H) x 355.0(L) mm ● Ultra compact Design (1U Size) ● Very High Power Density - 4.72 W/in³ ● Efficiency:≧ 80% at Max load of 115 ~ 230VAC ● low noise design <50dB @ full load ● Remote On/Off Control ● Current share with ORing diodes ● I2C Serial Bus Interface ● Tylersburg compliant ● RoHS compliant for all six substances
● Download |
|
| |
|
|
|
|
|
|
Input Voltage Input Frequency Input Current
Inrush Current
Power Factor
Earth Leakage Current |
|
90 - 264VAC 47 - 63 Hz 8A max at 115V 4A max at 230V 40A max at 115V 60A max at 230V > 0.98 at 115V / 60Hz > 0.94 at 230V / 50Hz 3.0mA max at 264V / 50Hz | |
|
|
|
Efficiency Power Density Signals MTBF
|
|
4.72 W/in³ Power good, TTL compatible 100 kHrs per Bellcore SR-332 ISSUE1 at 25°C ambient
| |
|
|
|
| |
|
|
Output Voltage Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Over / Undershoot Transient Response
Over Voltage Protection
Over Temperature Protection
Over Current Protection
Short Circuit Protection Temperature Coefficient Remote On/Off
Current Share |
|
See table See table < 500mSec maximum < 50mSec measured at 10% to 90% 14 mS/110V < 10% max at turn on/off < 4% max piation, recovery to within 1% in 1mSec for 25% load change +3.3V:3.9V ~ 4.5V +5V:5.7V ~ 6.5V +12V1-3:13.3V ~ 14.5V Primary & secondary protection with auto recovery +3.3V:19.8A ~ 27A +5V:19.8A ~ 27A +12V1-3:17.6A ~ 24A No damage, resistance ≦ 0.01Ω ≦0.05% per °C after 30min. operating On = PSON ≦ 0.8V, low Off = PSON ≦ 2.4V, high, open 2 supplies to share within ± 10% | |
|
| |
|
|
|
Operating Temperature Operating Humidity Storage Temperature Operating Altitude Shock Operating Non-Operating Vibration Operating Non-Operating |
|
0 to 40°C 5 - 90%, Non-condensing -40°C to +70°C Sea level to 7000 feet 5G, 11mSec, half sine 3 axes 30G, 11mSec, half sine 3 axes 0.5G, 10 Hz to 500 Hz, 3 axes 2G, 10 Hz to 500 Hz, 3 axes | |
|
|
|
|
Emissions
Harmonic Currents Voltage Flicker EFT/Burst Surge Conducted Immunity Safety Approvals |
|
EN55022, class B Conducted EN55022, class B Radiated EN61000-3-2, class D EN61000-3-3 EN61000-4-4, level 3 Perf Criteria B EN61000-4-5, level 3 Pref Criteria B EN61000-4-6, 10Vrms, Pref Criteria A UL/cUL60950-1, TUV, CB, CE FCC Report | |
|
| | |
Application |
|
● |
Broadcasting |
|
● |
Industrial |
|
● |
Server |
|
● |
Storage |
|
● |
Networking |
|
● |
Workstation |
| |
Output |
Minimum Load |
Maximum Load |
Condition |
Ripple & Noise |
+3.3V |
1.5A |
18A |
Combined +3.3V & +5V power ≤ 140W.
Combined 12V1~3 current ≤ 32A.
Maximum continuous total DC output power should not exceed 450W. | |
50mV p-p |
+5V |
1A |
18A |
50mV p-p |
+12V1 |
1A |
16A |
120mV p-p |
+12V2 |
1A |
16A |
120mV p-p |
+12V3 |
0A |
16A |
120mV p-p |
-12V |
0A |
0.5A |
120mV p-p |
+5VSB |
0.1A |
3A |
50mV p-p | |