JK-SMD0603系列自复保险丝
Electrical
characteristics(25℃)
Model | V max | Imax | I hold | I trip | Pd | Maximum time to
trip | Resistance |
(V dc) | (A) | (A) | (A) | Max. (W) | Current | Time | R min | R1max |
(A) | (Sec) | (W) | (W) |
JK-SMD0603-005 | 24.0 | 20 | 0.05 | 0.15 | 0.50 | 0.2 | 1.00 | 3.0 | 35.00 |
JK-SMD0603-010 | 15.0 | 40 | 0.10 | 0.30 | 0.50 | 0.5 | 1.00 | 0.9 | 8.00 |
JK-SMD0603-020 | 9.0 | 40 | 0.20 | 0.40 | 0.50 | 1.00 | 0.6 | 0.55 | 3.50 |
JK-SMD0603-025 | 9.0 | 40 | 0.25 | 0.55 | 0.50 | 8.0 | 0.08 | 0.500 | 3.00 |
JK-SMD0603-030 | 6.0 | 40 | 0.30 | 0.70 | 0.50 | 8A | 0.10 | 0.300 | 2.00 |
JK-SMD0603-035 | 6.0 | 40 | 0.35 | 0.75 | 0.50 | 8A | 0.10 | 0.200 | 1.40 |
I hold =Hold Current. Maximum current device will not
trip in 25°C still air.
I trip =Trip Current. Minimum current at which the
device will always trip in 25°Cstill air.
V max =Maximum operating voltage device can
withstand without damage at rated current(Imax).
Imax =Maximum fault current device can withstand without
damage at rated voltage(V max).
Pd=Maximum
power dissipation when device is in the tripped state in 25°C still air environment
at rated voltage.
R min/max =Minimum/Maximum device resistance prior to
tripping at 25°C.
R1max = Maximum device resistance is measured one
hour post reflow.