characteristics(25℃)
Model | V max | I max | I hold | I trip | Time to trip | R25 |
@25°C | @25°C | Current | Time | R min | R1max |
(V dc) | (A) | (A) | (A) | (A) | (Sec) | (W) | (W) |
JK-nSMD005 | 60.0 | 100 | 0.05 | 0.15 | 0.25 | 1.50 | 3.600 | 50.000 |
JK-nSMD010 | 60.0 | 100 | 0.10 | 0.25 | 0.5 | 1.00 | 1.600 | 15.000 |
JK-nSMD010-33 | 33.0 | 100 | 0.10 | 0.25 | 0.5 | 1.00 | 1.600 | 15.000 |
JK-nSMD012 | 30 | 100 | 0.12 | 0.29 | 1.00 | 0.20 | 1.350 | 10.00 |
JK-nSMD016 | 30 | 100 | 0.16 | 0.37 | 1.00 | 0.30 | 1.000 | 4.50 |
JK-nSMD020 | 24.0 | 100 | 0.20 | 0.46 | 8.0 | 0.08 | 0.350 | 3.500 |
JK-nSMD025 | 16.0 | 100 | 0.25 | 0.50 | 8.0 | 0.08 | 0.350 | 2.500 |
JK-nSMD030 | 16.0 | 100 | 0.30 | 0.65 | 8.0 | 0.10 | 0.250 | 2.00 |
JK-nSMD035 | 16.0 | 100 | 0.35 | 0.75 | 8.0 | 0.10 | 0.250 | 1.300 |
JK-nSMD050 | 6.0 | 100 | 0.50 | 1.00 | 8.0 | 0.10 | 0.150 | 0.700 |
JK-nSMD050-13.2 | 13.2 | 100 | 0.50 | 1.00 | 8.0 | 0.10 | 0.150 | 0.700 |
JK-nSMD050-16 | 16 | 100 | 0.50 | 1.00 | 8.0 | 0.10 | 0.150 | 0.750 |
JK-nSMD050-24 | 24 | 100 | 0.50 | 1.00 | 8.0 | 0.10 | 0.150 | 0.750 |
JK-nSMD075 | 6.0 | 100 | 0.75 | 1.50 | 8.0 | 0.20 | 0.090 | 0.500 |
JK-nSMD075-13.2 | 13.2 | 100 | 0.75 | 1.50 | 8.0 | 0.20 | 0.090 | 0.500 |
JK-nSMD075-16 | 16 | 100 | 0.75 | 1.50 | 8.0 | 0.20 | 0.090 | 0.500 |
JK-nSMD100 | 6.0 | 100 | 1.00 | 1.80 | 8.0 | 0.30 | 0.055 | 0.270 |
JK-nSMD100-13.2 | 13.2 | 100 | 1.00 | 1.80 | 8.0 | 0.30 | 0.055 | 0.270 |
JK-nSMD100-16 | 16 | 100 | 1.00 | 1.80 | 8.0 | 0.30 | 0.055 | 0.330 |
JK-nSMD110 | 8.0 | 100 | 1.10 | 1.80 | 8.0 | 0.30 | 0.050 | 0.230 |
JK-nSMD150 | 6.0 | 100 | 1.50 | 3.00 | 8.0 | 1.00 | 0.040 | 0.130 |
JK-nSMD200 | 6.0 | 100 | 2.00 | 3.50 | 8.0 | 1.0 | 0.018 | 0.080 |
IH=Hold current:
maximum current at which the device will not trip at 25°C still air.
IT =Trip current: minimum current at which the
device will always at 25°Cstill air.
V max =Maximum voltage device can withstand without
damage at rated current.
I max =Maximum fault current device can withstand without
damage at rated voltage.
T trip=Maximum
time to trip(s) at assigned current.
Pd=Typical
power dissipation: typical amount of power dissipated by the decice when in
state air environment
R min=Minimum
device resistance at 25°C prior to tripping.
R max=Maximum
device resistance at 25°C prior to tripping.